Low-dose Mode Cath Lab For Neuro Intervention

Low-dose Mode Cath Lab For Neuro Intervention

Low-dose mode cath lab for Neuro intervention clinical treatment

Product Introduction

Low-dose Mode Cath Lab For Neuro Intervention Advantages

  • Ultra-smart 7-axis gantry, ultra-wide scanning range.

  • one key operation, convenient and precise surgical position switching

  • Liquid metal bearing X ray tube, longer service life.

  • 5A image processing technology

  • Low-dose platform: "We-dose" platform provides better and full protection for doctors

Product Video:

Product Index:

High-speed X ray Tube

  • Dual focus: 0.6mm/1.0mm

  • Tube cooling method: Air, Water, Oil

  • Target angle:11°

  • Advanced WAD multiple cooling technology

High-voltage Generator

  • Power:100kW

  • Maximum current  1000mA

  • Inverter frequency: 160KHz~400KHz

Collimator

  • The automatic insertion technology is adopted to eliminate the soft rays of the tube without manual intervention.   

  • Electric lung field iris  

  • Automatic X-ray filed adjustment

Dynamic FPD

  • Material: A-Si Cesium Iodide

  • Nominal area: 30cm×30cm

Catheterization Table   

  • Full caron fiber floating table surface  

  • Length× Width: 300cm × 63.5cm 

  • Vertical movement range: 140cm   

  • Lateral movement range: 36cm 

  • The lowest height: 72cm  

Image Acquisition 

  • Acquisition mode: CINE, DSA, rotating DSA/ rotating acquisition, DA acquisition, Fluoroscopy, lower limb stepping DSA acquisition  

  • CINE: maximum acquisition speed: 30 FPS; 1.5K matrix acquisition  

  • Standard DSA model: maximum acquisition speed: 30 FPS; 1.5K matrix acquisition, real-time DSA

  • Digital pulse has 6 kind different rate: 1,2,4,8,15,30 FPS

  • Subtraction & non-subtraction switching

Imaging Processing

  • Dynamic image optimization and noise reduction

  • Adaptive edge enhancement

  • Window width/window level adjustment, sharpness adjustment, Gamma adjustment

Low-dose platform

  • Low-dose image acquisition

  • The position of the shading plate and filter can be adjusted without radiation on the last frame of the fluoroscopic image

  • Radiation dose monitoring function: surface dose rate during fluoroscopy; accumulated dose display

Clinical Images:


angiography machine

Low-dose Mode Cath Lab For Neuro Intervention

angiography system

Low-dose Mode Cath Lab For Neuro Intervention



Hot Tags: low-dose mode cath lab for neuro intervention, suppliers, factory, pricelist, Italy, Europe, CE, for sale, interventional angiography, cardiac vascular angiography, Peripheral Interventional Angiography System, 3D Dsa, interventional radiology, Interventional Cardio System